Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Boston Pizza (Southport): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST FireShield FS1004G <br>FACP Location: Main Entrance<br />System Type: Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Temporal <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: 2022<br />Year Opened: 1978
| FACP: EST FireShield FS1004G <br>FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Temporal <br>Strobes Synchronized: No<br />Date of last known Upgrade: 2022<br />Year Opened: 1978
|}
|}
'''Boston Pizza''' is Canada's largest casual restaurant chain. They operate 366 locations in Canada, and about 45 chains in the USA under the name "Boston's". This particular restaurant is located at 10456 Southport Road Southwest, in Calgary, Alberta, Canada. The restaurant opened in 1978, and was renovated in 2006. The fire alarm system was installed following the renovation.
'''Boston Pizza''' is Canada's largest casual restaurant chain. They operate 366 locations in Canada, and about 45 chains in the USA under the name "Boston's". This particular restaurant is located at 10456 Southport Road SW, in Calgary, Alberta, Canada. The restaurant was built in 1978, and was renovated in 2006. The fire alarm system was installed following the renovation.
==System Specifications (2006-present)==
==System Specifications (2006-present)==
====FACP====
====FACP====
Line 18: Line 18:
====Automatic Detection Devices====
====Automatic Detection Devices====
There are System Sensor C2W-BA conventional photoelectric smoke detectors in all washrooms and at the top of every stairwell. There are System Sensor 5601A conventional fixed/rate-of-rise heat detectors in some areas. These were installed in 2022 replacing recalled Edwards detectors (C2M-PD photoelectric smoke detectors and 281B-PL rate-of-rise/fixed heat detectors).
There are System Sensor C2W-BA conventional photoelectric smoke detectors in all washrooms and at the top of every stairwell. There are System Sensor 5601A conventional fixed/rate-of-rise heat detectors in some areas. These were installed in 2022 replacing recalled Edwards detectors (C2M-PD photoelectric smoke detectors and 281B-PL rate-of-rise/fixed heat detectors).
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Restaurants]]
[[Category:Restaurants]]

Latest revision as of 16:26, 8 September 2024

System Specifications
FACP: EST FireShield FS1004G
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2022
Year Opened: 1978

Boston Pizza is Canada's largest casual restaurant chain. They operate 366 locations in Canada, and about 45 chains in the USA under the name "Boston's". This particular restaurant is located at 10456 Southport Road SW, in Calgary, Alberta, Canada. The restaurant was built in 1978, and was renovated in 2006. The fire alarm system was installed following the renovation.

System Specifications (2006-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST FireShield FS1004G conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are System Sensor C2W-BA conventional photoelectric smoke detectors in all washrooms and at the top of every stairwell. There are System Sensor 5601A conventional fixed/rate-of-rise heat detectors in some areas. These were installed in 2022 replacing recalled Edwards detectors (C2M-PD photoelectric smoke detectors and 281B-PL rate-of-rise/fixed heat detectors).

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all circuits.