| FACP: EST iO500 <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2014 <br />Year Opened: 1958
| FACP: EST iO500 <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2014 <br />Year Opened: 1958
|}
|}
'''The Crimson''' is an upscale hotel located at 200 Connaught Drive, in Jasper, Alberta, Canada. The hotel opened in 1958, and was extensively renovated in 2014. The fire alarm system was upgraded as part of the 2014 renovation.
'''The Crimson''' is an upscale hotel located at 200 Connaught Drive, in Jasper, Alberta, Canada. The hotel opened in 1958, and was extensively renovated in 2014. The fire alarm system was upgraded as part of the 2014 renovation.
Line 20: Line 20:
====Modules====
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Hotels]]
[[Category:Hotels]]
[[Category:Alberta]]
[[Category:Alberta]]

Latest revision as of 11:56, 14 October 2024

System Specifications
FACP: EST iO500
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: 2014
Year Opened: 1958

The Crimson is an upscale hotel located at 200 Connaught Drive, in Jasper, Alberta, Canada. The hotel opened in 1958, and was extensively renovated in 2014. The fire alarm system was upgraded as part of the 2014 renovation.

System Specifications (2014-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST iO500 addressable fire alarm system. The panel location is unknown. The system runs EST’s Signature addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All common areas have Edwards “Genesis” G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd).
All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount).
For exterior notification, there is an Edwards WG4RN-HVMC weatherproof horn/strobe (red, wall-mount, no marking, set to 60cd) at the right corner of the building.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the hotel’s common areas, mounted on EST SIGA-SB bases.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.