Churchill Station (Valley Line): Difference between revisions

From FireAlarmPedia
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Addressable <br />S...")
 
No edit summary
 
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2023
| FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: N/A <br />Year Opened: 2023
|}
|}
 
'''Churchill Station''' is a light rail train station in Edmonton, Alberta, Canada. This page will cover the Valley Line building, which serves as a connector between the Valley Line and Metro/Capital Line platforms. The building was built in 2023, and the fire alarm system is original.
'''Churchill Station''' is a light rail train station in Edmonton, Alberta, Canada. This page will cover the Valley Line building, which serves as a connector between the Valley Line and Metro/Capital Line platforms. The building was built in 2023, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby.
There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby.
====Notification Appliances====
====Notification Appliances====
Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd). <br>Some areas have System Sensor PC2RLA-E horn/strobes (red, ceiling-mount, set to 15cd). <br>There are a System Sensor SRLA-E remote strobes (red, wall-mount, set to 15cd) in the Metro/Capital Line building above the doors to this building.
Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd). <br>Some areas have System Sensor PC2RLA-E horn/strobes (red, ceiling-mount, set to 15cd). <br>There are a System Sensor SRLA-E remote strobes (red, wall-mount, set to 15cd) in the Metro/Capital Line building above the doors to this building.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases.
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases.
====Modules====
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br>There are Notifier ISO-XA isolator modules on the SLC.
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br>There are Notifier ISO-XA isolator modules on the SLC.
 
====EOLs====
====EOLs====
There are Notifier EOL-CR end of line resistor plates on all signal circuits.
There are Notifier EOL-CR end of line resistor plates on all signal circuits.
====Accessories====
====Accessories====
There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system.
There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system.
[[Category:Edmonton]]
[[Category:Edmonton]]
[[Category:Train Stations]]
[[Category:Train Stations]]

Latest revision as of 16:43, 23 September 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: N/A
Year Opened: 2023

Churchill Station is a light rail train station in Edmonton, Alberta, Canada. This page will cover the Valley Line building, which serves as a connector between the Valley Line and Metro/Capital Line platforms. The building was built in 2023, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby.

Notification Appliances[edit | edit source]

Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd).
Some areas have System Sensor PC2RLA-E horn/strobes (red, ceiling-mount, set to 15cd).
There are a System Sensor SRLA-E remote strobes (red, wall-mount, set to 15cd) in the Metro/Capital Line building above the doors to this building.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier ISO-XA isolator modules on the SLC.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all signal circuits.

Accessories[edit | edit source]

There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system.