Earls (Dalhousie): Difference between revisions

From FireAlarmPedia
No edit summary
(ass)
 
Line 25: Line 25:
|  
|  
|-
|-
| FACP: Notifier SFP-400B <br>FACP Location: Lobby<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Continuous <br>Strobes Synchronized: No <br />Date of last known Upgrade: N/A <br />Year Decomissioned: 2012
| FACP: Notifier SFP-400B <br>FACP Location: Lobby<br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Continuous <br>Strobes Synchronized: No <br />Date of last known Upgrade: N/A <br />Year Decomissioned: 2012
|}
|}
==== FACP ====
==== FACP ====

Latest revision as of 17:01, 25 September 2024

System Specifications
FACP: Simplex 4006
FACP Location: Lobby
System Type: SIngle-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Date of last known Upgrade: 2012
Year Opened: 1996

Earls is a casual restaurant chain. This particular restaurant is located at #605 5005 Dalhousie Dr NW, Calgary, AB. It was built in 1996, and had a renovation in 2012. The fire alarm system was installed after the renovation, but most of the pull stations are original.

System Specifications (2012-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4006 conventional fire alarm system. The panel is located in the lobby, and is specifically model 4006-9122 (beige door with LED annunciator). The system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Simplex "TrueAlert" 4906-9127 horn/strobes (red, wall-mount, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

Most pull stations are the original Notifier NFM-950B conventional pull stations. There is a Mircom MS-401 conventional pull station in the kitchen as a deficiency replacement.

Automatic Detection Devices[edit | edit source]

There is a Simplex 4098-9615 fixed temperature/rate of rise heat detector in the kitchen, and a Simplex 4098-9601 photoelectric smoke detector in the entrance. Both detectors are mounted on 4098-9788 bases.

Former System Specifications (1996-2012)[edit | edit source]

System Specifications
FACP: Notifier SFP-400B
FACP Location: Lobby
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Decomissioned: 2012

FACP[edit | edit source]

The building was protected by a Notifier SFP-400B conventional fire alarm system. The panel was located in the lobby. The system coding was continuous.

Notification Appliances[edit | edit source]

All notification appliances were System Sensor MASS24LO sounder/strobes (red, wall-mount, 1.5cd). These were likely set to 800Hz continuous.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NFM-950B conventional pull stations. These are still installed on the 4006.

Automatic Detection Devices[edit | edit source]

There were System Sensor 1412A conventional 2-wire ionization smoke detectors, located throughout.