Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

2160 78 Avenue NE, Calgary: Difference between revisions

From FireAlarmPedia
(Very interesting Simplex system! Sad to see it go..)
(Yet another revamp. This one is particularly special to me as it was the first system I ever worked on.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4008 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC<br />Date of last known Upgrade: 2005 <br />Year Opened: 1950s
| FACP: Simplex 4008  
FACP Location: Main Entrance<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC
 
System Coding: Temporal
 
Strobes Synchronized: No<br />Date of last known Upgrade: 2005 <br />Year Opened: 1950s
|}
|}
'''2160 78 Avenue NE''' is the address of Air Canada's ground support equipment building. It is the main service shop for all ground vehicles in Air Canada's fleet. It was built in the 1950s, but the system was installed in 2005.
'''2160 78 Avenue NE''' is the address of Air Canada's ground support equipment building. It is the main service shop for all ground vehicles in Air Canada's fleet. It was built in the 1950s, but the system was installed in 2005.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Simplex 4008 addressable fire alarm system. The panel is located in the main entrance.  When in alarm, the system codes all the horns to code 3, and synchronizes the strobes.
The building is protected by a Simplex 4008 addressable fire alarm system. The panel is located at the main entrance.  The system runs Simplex's IDNet addressable protocol, and the system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are System Sensor "SpectrAlert" P1224MCA horn/strobes (red, wall mount). They are set on 30 candela, and electromechanical tone.
All notification appliances are System Sensor "SpectrAlert" P1224MCA horn/strobes (red, wall mount). They are set on 30 candela, and electromechanical tone.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
Most of the pull stations are Simplex 4099-9001 addressable, single action T-Bar IDNet pull stations.  The paint booth, however, has Potter MPEX explosion-proof pull stations, wired to 4090-9001 addressable modules, most likely due to Simplex not making any addressable explosion-proof pull stations at the time.
All pull stations but two are Simplex 4099-9001 addressable single-action pull stations.  The paint booth has Potter MPEX explosion-proof conventional single-action pull stations.  These are wired to Simplex 4090-9001 addressable monitor modules.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Simplex 4098-9714 addressable photoelectric smoke detectors and Simplex 4098-9734 addressable fixed/rate-of-rise heat detectors in the offices, hallways, and low-ceiling areas in the main shop.
There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors and Simplex 4098-9734 addressable fixed/rate-of-rise heat detectors in the offices, hallways, and low-ceiling areas of the main shop. All detectors are mounted on Simplex 4098-9792 addressable bases.
 
==Bonus Information==
==Bonus Information==
The building will be demolished in 2028, and the staff of this site will be getting the system!
The building will be demolished in 2028, and the staff of this site will be getting the system!

Revision as of 12:30, 8 November 2022

System Specifications
FACP: Simplex 4008

FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage:24VDC

System Coding: Temporal

Strobes Synchronized: No
Date of last known Upgrade: 2005
Year Opened: 1950s

2160 78 Avenue NE is the address of Air Canada's ground support equipment building. It is the main service shop for all ground vehicles in Air Canada's fleet. It was built in the 1950s, but the system was installed in 2005.

System Specifications

FACP

The building is protected by a Simplex 4008 addressable fire alarm system. The panel is located at the main entrance. The system runs Simplex's IDNet addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are System Sensor "SpectrAlert" P1224MCA horn/strobes (red, wall mount). They are set on 30 candela, and electromechanical tone.

Initiating Devices

Pull Stations

All pull stations but two are Simplex 4099-9001 addressable single-action pull stations. The paint booth has Potter MPEX explosion-proof conventional single-action pull stations. These are wired to Simplex 4090-9001 addressable monitor modules.

Automatic Detection Devices

There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors and Simplex 4098-9734 addressable fixed/rate-of-rise heat detectors in the offices, hallways, and low-ceiling areas of the main shop. All detectors are mounted on Simplex 4098-9792 addressable bases.

Bonus Information

The building will be demolished in 2028, and the staff of this site will be getting the system!