| FACP: Simplex 4007ES<br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br />Date of last known Upgrade: 2017<br />Year Opened: 1996
| FACP: Simplex 4007ES
FACP Location: Main Entrance<br />System Type: Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC  
 
System Coding: Temporal
 
Strobes Synchronized: SmartSync<br />Date of last known Upgrade: 2017<br />Year Opened: 1996
|}
|}
Safeway is a chain of grocery stores in North America. This particular location is located in Shawnessy, SE Calgary and was built in 1996. The current fire alarm system is from 2017, but all pull stations are original.  
Safeway is a chain of grocery stores in North America. This particular location is located in Shawnessy, SE Calgary and was built in 1996. The current fire alarm system is from 2017, but all pull stations are original.  
 
== System Specifications (2017-present) ==
== System Specifications (2017-present) ==
==== FACP ====
==== FACP ====
The fire alarm panel is a Simplex 4007ES. It was installed in 2017, and it is set up in a non-addressable manner. The main panel is located in the main entrance. The 4007ES replaced an EST 6616.
The store is protected by a Simplex 4007ES conventional fire alarm system. The panel is located at the main entrance, and was installed in 2017, replacing an EST 6616. The system coding is temporal.
 
==== Notification Appliances ====
==== Notification Appliances ====
The notification appliances consist of Simplex TrueAlert 4906-9127 (red, wall) horn/strobes. These were installed in 2017, replacing the original bells. It is unknown if the horn/strobe replacing the bell that rang for a delivery goes off for one, but it is in the same place that the bell was.
The notification appliances are all Simplex "TrueAlert" 4906-9127 (red, wall-mount, multi-candela) horn/strobes.  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
The pull stations are the original Edwards 270-SPO conventional pull stations, and were not replaced despite the upgrade.
The pull stations are Edwards 270-SPO, from 1996. They are original to the store.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
Waterflow protection, no visible detectors.
None noticed.
 
== Former System Specifications (1996-2017) ==
== Former System Specifications (1996-2017) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 34: Line 30:
|  
|  
|-
|-
| FACP: EST 6616 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Final Year In Active Service: 2017
| FACP: EST 6616  
FACP Location: Main Entrance<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Continuous<br />Date of last known Upgrade: N/A <br />Final Year In Active Service: 2017
|}
|}
==== FACP ====
==== FACP ====
The original fire alarm panel was an EST 6616 from 1996. It was replaced in 2017 with the current Simplex 4007ES.
The store was formerly protected by an EST 6616 conventional fire alarm system. The panel was located in the main entrance. The system coding was continuous
 
==== Notification Appliances ====
==== Notification Appliances ====
The original notification appliances were Edwards 439D-10AWC vibrating bells. These were replaced in 2017 with Simplex TrueAlert horn/strobes.
The original notification appliances were Edwards 439D-10AWC vibrating bells (10" gong).  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations were and still are Edwards 270-SPO. These are the only devices that were continued to be used on the new 4007ES.
The pull stations were and still are the Edwards 270-SPO. These are the only devices that were continued to be used on the new 4007ES.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
Not available
None were noticed.
 
== Bonus Information ==
== Bonus Information ==
One of the original fire bells (Edwards 439D-10AWC) was wired to a doorbell button as well as the EST 6616, and when the doorbell button was pressed, the bell would ring softly to indicate a delivery. It was probably on 12VDC. It is unknown if the horn/strobe there goes off for deliveries, but it is in the same place as the bell that was there, as all the bells were replaced in 2017.
One of the original fire bells (Edwards 439D-10AWC) was wired to a doorbell button as well as the EST 6616, and when the doorbell button was pressed, the bell would ring softly to indicate a delivery. It was probably on 12VDC. It is unknown if the horn/strobe there goes off for deliveries, but it is in the same place as the bell that was there, as all the bells were replaced in 2017.
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 01:04, 22 November 2022

System Specifications
FACP: Simplex 4007ES

FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage:24VDC

System Coding: Temporal

Strobes Synchronized: SmartSync
Date of last known Upgrade: 2017
Year Opened: 1996

Safeway is a chain of grocery stores in North America. This particular location is located in Shawnessy, SE Calgary and was built in 1996. The current fire alarm system is from 2017, but all pull stations are original.

System Specifications (2017-present)

FACP

The store is protected by a Simplex 4007ES conventional fire alarm system. The panel is located at the main entrance, and was installed in 2017, replacing an EST 6616. The system coding is temporal.

Notification Appliances

The notification appliances are all Simplex "TrueAlert" 4906-9127 (red, wall-mount, multi-candela) horn/strobes.

Initiating Devices

Pull Stations

The pull stations are the original Edwards 270-SPO conventional pull stations, and were not replaced despite the upgrade.

Automatic Detection Devices

Waterflow protection, no visible detectors.

Former System Specifications (1996-2017)

System Specifications
FACP: EST 6616

FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Continuous
Date of last known Upgrade: N/A
Final Year In Active Service: 2017

FACP

The store was formerly protected by an EST 6616 conventional fire alarm system. The panel was located in the main entrance. The system coding was continuous

Notification Appliances

The original notification appliances were Edwards 439D-10AWC vibrating bells (10" gong).

Initiating Devices

Pull Stations

The pull stations were and still are the Edwards 270-SPO. These are the only devices that were continued to be used on the new 4007ES.

Automatic Detection Devices

Not available

Bonus Information

One of the original fire bells (Edwards 439D-10AWC) was wired to a doorbell button as well as the EST 6616, and when the doorbell button was pressed, the bell would ring softly to indicate a delivery. It was probably on 12VDC. It is unknown if the horn/strobe there goes off for deliveries, but it is in the same place as the bell that was there, as all the bells were replaced in 2017.