Boston Pizza (Shawnessy): Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
Line 10: Line 10:
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The building is protected by a Mircom FA-106 conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is likely continuous. This panel was installed on June 5th, 2020 replacing a Notifier SFP-400B.
The building is protected by a Mircom FA-106 conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is likely continuous. This panel was installed on June 5th, 2020 replacing a Notifier SFP-400B.
==== Notification Appliances ====
====Notification Appliances====
All notification appliances but one are Wheelock MBS-G6-24 motor bell/strobes (6" gong, 1.5cd). One area has a Notifier KMS-6-24A motor bell (6" gong) as a deficiency replacement, mounted on the original Wheelock strobe plate.  
All notification appliances but one are Wheelock MBS-G6-24 motor bell/strobes (6" gong, 1.5cd). One area has a Notifier KMS-6-24A motor bell (6" gong) as a deficiency replacement, mounted on the original Wheelock strobe plate.  
=== Initiating Devices ===
===Initiating Devices===
==== Pull Stations ====
====Pull Stations====
All pull stations are Mircom MS-401 conventional single-action pull stations. These were installed in December 2022 replacing Notifier MPS-950B pull stations.
All pull stations are Mircom MS-401 conventional single-action pull stations. These were installed in December 2022 replacing Notifier MPS-950B pull stations.
==== Automatic Detection Devices ====
====Automatic Detection Devices====
None present. There is a kitchen suppression system, and no sprinkler system.
None present. There is a kitchen suppression system, and no sprinkler system.
=== Bonus Information ===
===Bonus Information===
Permit issued for FACP upgrade on June 5th, 2020.  
Permit issued for FACP upgrade on June 5th, 2020.  


Permit information: Fire Alarm Repair - Boston Pizza Shawnessy.
Permit information: Fire Alarm Repair - Boston Pizza Shawnessy.
[[]
[[Category:Calgary]]
[[Category:Restaurants]]

Revision as of 18:22, 23 May 2024

System Specifications
FACP: Mircom FA-106
FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2022
Year Opened: 1996

Boston Pizza is Canada's largest casual restaurant chain. This particular restaurant is located at 235 Shawville Boulevard Southeast, in the Shawnessy shopping area of Calgary, Alberta, Canada. The restaurant opened in 1996, and only the notification appliances are original.

System Specifications

FACP

The building is protected by a Mircom FA-106 conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is likely continuous. This panel was installed on June 5th, 2020 replacing a Notifier SFP-400B.

Notification Appliances

All notification appliances but one are Wheelock MBS-G6-24 motor bell/strobes (6" gong, 1.5cd). One area has a Notifier KMS-6-24A motor bell (6" gong) as a deficiency replacement, mounted on the original Wheelock strobe plate.

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401 conventional single-action pull stations. These were installed in December 2022 replacing Notifier MPS-950B pull stations.

Automatic Detection Devices

None present. There is a kitchen suppression system, and no sprinkler system.

Bonus Information

Permit issued for FACP upgrade on June 5th, 2020.

Permit information: Fire Alarm Repair - Boston Pizza Shawnessy.