More actions
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Addressable <br />S...") |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, | | FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: N/A <br />Year Opened: 2023 | ||
|} | |} | ||
'''Churchill Station''' is a light rail train station in Edmonton, Alberta, Canada. This page will cover the Valley Line building, which serves as a connector between the Valley Line and Metro/Capital Line platforms. The building was built in 2023, and the fire alarm system is original. | |||
'''Churchill Station''' is a light rail train station in Edmonton, Alberta, Canada. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Notifier NFS-320C addressable fire alarm system. | The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal. | ||
=====Annunciators===== | =====Annunciators===== | ||
There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby. | There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd). | Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd). <br>Some areas have System Sensor PC2RLA-E horn/strobes (red, ceiling-mount, set to 15cd). <br>There are a System Sensor SRLA-E remote strobes (red, wall-mount, set to 15cd) in the Metro/Capital Line building above the doors to this building. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Notifier NBG-12LX addressable dual-action pull stations. | All pull stations are Notifier NBG-12LX addressable dual-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases. | There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases. | ||
====Modules==== | ====Modules==== | ||
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br>There are Notifier ISO-XA isolator modules on the SLC. | ||
====EOLs==== | ====EOLs==== | ||
There are Notifier EOL-CR end of line resistor plates on all signal circuits. | There are Notifier EOL-CR end of line resistor plates on all signal circuits. | ||
====Accessories==== | ====Accessories==== | ||
There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system. | There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system. | ||
[[Category:Edmonton]] | [[Category:Edmonton]] | ||
[[Category:Train Stations]] | [[Category:Train Stations]] |
Latest revision as of 16:43, 23 September 2024
System Specifications |
---|
FACP: Notifier NFS-320C FACP Location: Unknown System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, System Sensor Date of last known Upgrade: N/A Year Opened: 2023 |
Churchill Station is a light rail train station in Edmonton, Alberta, Canada. This page will cover the Valley Line building, which serves as a connector between the Valley Line and Metro/Capital Line platforms. The building was built in 2023, and the fire alarm system is original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
Annunciators[edit | edit source]
There is a Notifier LCD2-80 annunciator paired with two Notifier ACM-24AT annunciators in the main lobby.
Notification Appliances[edit | edit source]
Most notification appliances are System Sensor “L-Series” P2RLA-E horn/strobes (red, wall-mount, set to 15cd).
Some areas have System Sensor PC2RLA-E horn/strobes (red, ceiling-mount, set to 15cd).
There are a System Sensor SRLA-E remote strobes (red, wall-mount, set to 15cd) in the Metro/Capital Line building above the doors to this building.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases.
Modules[edit | edit source]
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier ISO-XA isolator modules on the SLC.
EOLs[edit | edit source]
There are Notifier EOL-CR end of line resistor plates on all signal circuits.
Accessories[edit | edit source]
There is a TOA RM-200SF emergency paging microphone next to the annunciator; this microphone is connected to the building’s public address system.