More actions
(→FACP) |
|||
Line 5: | Line 5: | ||
==== FACP ==== | ==== FACP ==== | ||
The fire alarm panel is a Fire-Lite MS-4. It was previously owned by [[User:AdenK2333]] and [[User:Twentytwo22]]. It was previously used in the [[Barndominium]]. When the system goes into alarm, it does continuous. The panel has troubles and NAC faults, but that is because there's no resistors at the end of the IDCs or NACs. | The fire alarm panel is a Fire-Lite MS-4. It was previously owned by [[User:AdenK2333]] and [[User:Twentytwo22]]. It was previously used in the [[Barndominium]]. When the system goes into alarm, it does continuous (or also code 3 if only the bells or horns are hooked up). The panel has troubles and NAC faults, but that is because there's no resistors at the end of the IDCs or NACs. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== |
Revision as of 11:59, 6 January 2021
YYCsFireAlarmNimrod's Basement (name may be subject to change) is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by User:YYCsFireAlarmNimrod.
System Specifications
- Note: YYCsFireAlarmNimrod frequently modifies the fire alarm system, hence the "can range from" and "usually consist" parts. Although he frequently modifies it, it is always powered up. He can pull the alarm on it any time he wants to without being fined as it is a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency.
FACP
The fire alarm panel is a Fire-Lite MS-4. It was previously owned by User:AdenK2333 and User:Twentytwo22. It was previously used in the Barndominium. When the system goes into alarm, it does continuous (or also code 3 if only the bells or horns are hooked up). The panel has troubles and NAC faults, but that is because there's no resistors at the end of the IDCs or NACs.
Notification Appliances
The notification appliances usually consist of a Simplex 2901-9720 motor bell, and a Gentex "Commander 3" GEC3-24WR horn/strobe, set to random tones for each time he modifies the system, and sometimes just the strobe. The 2901-9720 came out of R.T. Alderman School. Other notification appliances used are an Edwards 892-2B with only the strobe hooked up, as the horn doesn't work.
Initiating Devices
Pull Stations
The pull stations usually consist of a Simplex 2099-9901 (4251-20, but with concave handle), a Simplex 2099-9754, and an Edwards 270-SPOWB (bilingual). The older Simplex came out of R.T. Alderman School. Other pull stations used sometimes are an ADT B5009.
Automatic Detection Devices
The only automatic detection device is a Simplex 2098-9110 2-wire ionization smoke detector. This smoke detector was used previously, it came out of R.T. Alderman School.