Forest Lawn Community & Neighborhood Services: Difference between revisions

From FireAlarmPedia
(No wonder there's a community service - in a bad part of Calgary!)
 
mNo edit summary
Line 7: Line 7:
| FACP: Mircom FX-2000 <br />FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS (MDL) <br />Date of last known Upgrade: 2010s <br />Year Opened: 1979
| FACP: Mircom FX-2000 <br />FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS (MDL) <br />Date of last known Upgrade: 2010s <br />Year Opened: 1979
|}
|}
 
'''The Forest Lawn Community & Neighborhood Services''' is a building providing provides community social-development services and youth-justice probation, located at 3810 17 Ave SE, Calgary, AB. It was built in 1979, and the fire alarm system was upgraded in the 2010s.
The Forest Lawn Community & Neighborhood Services is a building providing provides community social-development services and youth-justice probation, located at 3810 17 Ave SE, Calgary, AB. It was built in 1979, and the fire alarm system was upgraded in the 2010s.
 
== System Specifications (2010s-present) ==
== System Specifications (2010s-present) ==
==== FACP ====
==== FACP ====
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are from System Sensor’s “SpectrAlert Advance” line of products. <br> There is a mix of System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd) and System Sensor PC2RA horn/strobes (red, ceiling-mount, set to 15cd).  
All notification appliances are from System Sensor’s “SpectrAlert Advance” line of products. <br> There is a mix of System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd) and System Sensor PC2RA horn/strobes (red, ceiling-mount, set to 15cd).  
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Mircom MS-401AD addressable single-action pull stations.
All pull stations are Mircom MS-401AD addressable single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Mircom MIX-2251BA addressable photoelectric smoke detectors, mounted on System Sensor B210LPA bases. <br> There are also Mircom MIX-5351RBA addressable thermal heat detectors installed on System Sensor B300A-6 bases in some areas.  
There are Mircom MIX-2251BA addressable photoelectric smoke detectors, mounted on System Sensor B210LPA bases. <br> There are also Mircom MIX-5351RBA addressable thermal heat detectors installed on System Sensor B300A-6 bases in some areas.  
==== Modules ====
==== Modules ====
There are System Sensor M500XA isolator modules on the SLC’s. <br> There is a System Sensor MDL synchronization module to synchronize the horn/strobes.
There are System Sensor M500XA isolator modules on the SLC’s. <br> There is a System Sensor MDL synchronization module to synchronize the horn/strobes.

Revision as of 00:31, 14 February 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance Vestibule
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, SS (MDL)
Date of last known Upgrade: 2010s
Year Opened: 1979

The Forest Lawn Community & Neighborhood Services is a building providing provides community social-development services and youth-justice probation, located at 3810 17 Ave SE, Calgary, AB. It was built in 1979, and the fire alarm system was upgraded in the 2010s.

System Specifications (2010s-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are from System Sensor’s “SpectrAlert Advance” line of products.
There is a mix of System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd) and System Sensor PC2RA horn/strobes (red, ceiling-mount, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices

There are Mircom MIX-2251BA addressable photoelectric smoke detectors, mounted on System Sensor B210LPA bases.
There are also Mircom MIX-5351RBA addressable thermal heat detectors installed on System Sensor B300A-6 bases in some areas.

Modules

There are System Sensor M500XA isolator modules on the SLC’s.
There is a System Sensor MDL synchronization module to synchronize the horn/strobes.