FACP: Simplex 4006
FACP Location: Lobby System Coding: Temporal Strobes Synchronized: Yes, SmartSync |
Earls is a casual restaurant chain. This particular restaurant is located at #605 5005 Dalhousie Dr NW, Calgary, AB. It was built in 1996, and had a renovation in 2012. The fire alarm system was installed after the renovation, but most of the pull stations are original.
System Specifications (2012-present)
FACP
The building is protected by a Simplex 4006 conventional fire alarm system. The panel is located in the lobby, and is specifically model 4006-9122 (beige door with LED annunciator). The system coding is temporal.
Notification Appliances
All notification appliances are Simplex "TrueAlert" 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices
Pull Stations
Most pull stations are the original Notifier NFM-950B conventional pull stations. There is a Mircom MS-401 conventional pull station in the kitchen as a deficiency replacement.
Automatic Detection Devices
There is a Simplex 4098-9615 fixed temperature/rate of rise heat detector in the kitchen, and a Simplex 4098-9601 photoelectric smoke detector in the entrance. Both detectors are mounted on 4098-9788 bases.
Former System Specifications (1996-2012)
| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: Notifier SFP-400B
FACP Location: Lobby
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Decomissioned: 2012
|}
FACP
The building was protected by a Notifier SFP-400B conventional fire alarm system. The panel was located in the lobby. The system coding was continuous.
Notification Appliances
All notification appliances were System Sensor MASS24LO sounder/strobes (red, wall-mount, 1.5cd). These were likely set to 800Hz continuous.
Initiating Devices
Pull Stations
All pull stations are Notifier NFM-950B conventional pull stations. These are still installed on the 4006.
Automatic Detection Devices
There were System Sensor 1412A conventional 2-wire ionization smoke detectors, located throughout.