Safeway (Shawnessy)

From FireAlarmPedia
Revision as of 15:07, 2 April 2023 by Twentytwo22 (talk | contribs)
System Specifications
FACP: Simplex 4007ES

FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage:24VDC

System Coding: Temporal

Strobes Synchronized: SmartSync
Date of last known Upgrade: 2017
Year Opened: 1996

Safeway is a chain of grocery stores in North America. This particular location is located at 70 Shawville Blvd SE, Calgary and was built in 1996. The current fire alarm system is from 2017, but all pull stations are original.

System Specifications (2017-present)

FACP

The store is protected by a Simplex 4007ES conventional fire alarm system. The panel is located at the main entrance, and was installed in 2017, replacing an EST 6616. The system coding is temporal.

Notification Appliances

The notification appliances are all Simplex "TrueAlert" 4906-9127 (red, wall-mount, multi-candela) horn/strobes.

Initiating Devices

Pull Stations

The pull stations are the original Edwards 270-SPO conventional pull stations, and were not replaced despite the upgrade.

Automatic Detection Devices

Waterflow protection, no visible detectors.

Former System Specifications (1996-2017)

System Specifications
FACP: EST 6616

FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Continuous
Date of last known Upgrade: N/A
Final Year In Active Service: 2017

FACP

The store was formerly protected by an EST 6616 conventional fire alarm system. The panel was located in the main entrance. The system coding was continuous

Notification Appliances

The original notification appliances were Edwards 439D-10AWC vibrating bells (10" gong).

Initiating Devices

Pull Stations

The pull stations were and still are the Edwards 270-SPO. These are the only devices that were continued to be used on the new 4007ES.

Automatic Detection Devices

Not available

Bonus Information

One of the original fire bells (Edwards 439D-10AWC) was wired to a doorbell button as well as the EST 6616, and when the doorbell button was pressed, the bell would ring softly to indicate a delivery. It was probably on 12VDC. It is unknown if the horn/strobe there goes off for deliveries, but it is in the same place as the bell that was there, as all the bells were replaced in 2017.