YYCsFireAlarmNimrod's Basement (name may be subject to change) is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by User:YYCsFireAlarmNimrod.

System Specifications

  • Note: YYCsFireAlarmNimrod frequently modifies the fire alarm system, hence the "can range from" and "usually consist" parts. He is currently receiving about 30 new parts, which will be used on the system. Although he frequently modifies it, it is always powered up. He can pull the alarm on it any time he wants to without being fined as it is a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency.

FACP

The fire alarm panel is a Fire-Lite MS-4 (made 2015). It was previously owned by User:AdenK2333 and User:Twentytwo22. It was previously used in the Barndominium. When the system goes into alarm, it does continuous (or also code 3 if only the bells or horns are hooked up). The panel has a Power Trouble, more specifically a Charger fault, caused by an unknown event. This was not caused by the current owner. The panel is slated for replacement soon, and the MS-4 will be used as a testing panel for some devices. The new fire alarm panel's model has been confirmed, and is currently being shipped from Ontario, however the model number will not be revealed here yet. The new panel is coming from YouTuber CJ9899, and the page will be updated on Monday when it arrives.

Notification Appliances

The notification appliances usually consist of a Simplex 2901-9720 motor bell and an EST "Integrity" 202-5A-T remote strobe. The 2901-9720 came out of R.T. Alderman School, and the Integrity came out of a Walmart in Cambridge, Ontario. Other notification appliances used are an Edwards 892-2B with only the strobe hooked up (the horn failed), EST "Integrity" 757-5A-T horn/strobes, and recently a Simplex 2901-9722 motor bell, and an EST "Genesis LED" G1-AVRF (red, wall mount, no FIRE marking) horn/strobe. The Integrity devices came from YouTuber CJ9899, and the 2901-9722 also came out of R.T. Alderman School. The Genesis LED horn/strobe came from User:Twentytwo22. There will be several new devices coming Monday, April 19th, so stay tuned for that!

Initiating Devices

Pull Stations

The pull stations are also changed out sometimes, but they consist of a Simplex 2099-9201 (4251-20), a Simplex 2099-9754, an ADT B5009, an FCI MS-2, but an "EPO & DISCONNECT" variant, which is meant for an emergency stop switch, a Fire-Lite BG-12L, and a GE 270-SPO. The Simplex 2099-9201 came out of R.T. Alderman School, and the GE 270-SPO was from User:Twentytwo22. Other pull stations include an Edwards 270-SPO pull station (1990s), a late 1990s Edwards 270-SPO pull station, an Edwards 275-C111 pull station, a Mircom MS-401 pull station, and three Mirtone 73303 pull stations. He also owns a Simplex 4099-9004 addressable single-action pull station with an LED, but as the system is conventional, it cannot be used.

Automatic Detection Devices

The automatic detection devices are a Simplex 2098-9110 2-wire ionization smoke detector, an Edwards C2M-PD photoelectric smoke detector, a System Sensor 5601A rate-of-rise/fixed temp heat detector, a System Sensor "i3" C2W-BA photoelectric smoke detector, and an Edwards 281B-PL rate-of-rise/fixed temperature heat detector. This smoke detector was used previously, it came out of R.T. Alderman School.